1.SC Codes
300
SC No.
Level
Error Name/Error Condition/Major Cause/Solution
SC753-
50
B
Perfect Binder: Internal temperature thermostat disconnect error
The A/D value of the internal temperature thermostat was detected below -20
degrees for 1 sec.
Internal temperature thermistor connector loose, broken, defective
Thermistor defective
Slave board defective
Reconnect the connector.
Replace the internal temperature thermistor.
Replace the slave board.
Replace the thermistor harness.
After the repairs, cancel the low performance mode, and then turn the power
off/on.
SC No.
Level
Error Name/Error Condition/Major Cause/Solution
SC753-
51
B
Perfect Binder: Internal temperature thermistor error
Temperature was detected above 10°C three consecutive times (sampled every
sec. for 1 min.).
Internal temperature thermistor connector loose, broken, defective
Thermistor defective
Slave board defective
Reconnect the connector.
Replace the internal temperature thermistor.
Replace the slave board.
Replace the thermistor harness.
After the repairs, cancel the low performance mode, and then turn the power
off/on.
SC No.
Level
Error Name/Error Condition/Major Cause/Solution
SC753-
52
B
Perfect Binder: Glue heater startup error 2
The warm-up temperature was above the +-5°C target for the glue vat
temperature. (Not detected within 100 sec. after machine warm-up.)
Internal temperature thermistor defective
Glue heater defective
Slave board defective
Reconnect the connector.
Replace the internal temperature thermistor.
Replace the gluing unit.

Table of Contents