1.SC Codes
309
Error Name/Error Condition/Major Cause/Solution
Reconnect the connector.
Replace the cover horizontal registration sensor (L).
Replace the slave control board.
Replace the sensor harness.
After the repairs, cancel the low performance mode, and then turn the power
off/on.
Error Name/Error Condition/Major Cause/Solution
Perfect Binder: Signature exit sensor adjustment low value error
The signature exit sensor A/D input value was higher than 3.2 to 3.54V, the A/D
input value did not enter the range 3.2 to 3.54V, even after cover registration
sensor output value output was raised 0.04V.
Signature exit sensor connector loose, broken, defective
Sensor defective
Slave control board disconnected, defective
Reconnect the connector.
Replace the signature exit sensor.
Replace the slave control board.
Replace the sensor harness.
After the repairs, cancel the low performance mode, and then turn the power
off/on.
Error Name/Error Condition/Major Cause/Solution
Perfect Binder: LE detect sensor adjustment low value error
The LE detect sensor A/D input value was higher than 3.2 to 3.54V, and the
sensor A/D input value did not enter the range 3.2 to 3.54V, even after the sensor
output value was raised 0.04V.
LE detect sensor connector loose, broken, defective
Sensor defective
Slave control board disconnected, defective
Reconnect the connector.
Replace the LE detect sensor.
Replace the slave control board.
Replace the sensor harness.
After the repairs, cancel the low performance mode, and then turn the power
off/on.