1.SC Codes
336
Error Name/Error Condition/Major Cause/Solution
Perfect Binder: Sub grip open position late error
At the start of the sub grip open operation, the SG open sensor did not go ON,
even after the SG motor had operated for 1500 ms.
SG motor drive board defective
SG open sensor defective
Harness connector loose, broken, defective
Slave control board defective
Reconnect the connector.
Replace the SG motor.
Replace the SG open sensor.
Replace the slave control board.
Replace the motor harness.
Replace the sensor harness.
After the repairs, cancel the low performance mode, and then turn the power
off/on.
Error Name/Error Condition/Major Cause/Solution
Perfect Binder: Sub grip open position lag error
At the start of the sub grip close operation, the SG open sensor did not go OFF,
even after the SG motor had operated for 500 ms.
SG open sensor defective
Harness connector loose, broken, defective
Slave control board defective
Reconnect the connector.
Replace the SG motor.
Replace the SG open sensor.
Replace the slave control board.
Replace the motor harness.
Replace the sensor harness.
After the repairs, cancel the low performance mode, and then turn the power
off/on.
Error Name/Error Condition/Major Cause/Solution
Perfect Binder: Sub grip close position late error
At the start of the sub grip close operation, the SG close sensor did not go ON,