1.SC Codes
338
Error Name/Error Condition/Major Cause/Solution
MG lift motor defective
MG HP sensor defective
Connector harness loose, broken, defective
Slave control board defective
Reconnect the connector.
Replace the MG lift motor.
Replace the MG HP sensor.
Replace the slave control board.
Replace the motor harness.
Replace the sensor harness.
After the repairs, cancel the low performance mode, and then turn the power
off/on.
Error Name/Error Condition/Major Cause/Solution
Perfect Binder: Main grip HP sensor lag error
During main grip lowering, the MG HP sensor did not go OFF, even though
the main grip lift motor had operated for 1455 ms.
MG HP sensor did not go ON when the main grip moved from down position
to up position.
MG lift motor defective
MG HP sensor defective
Connector harness loose, broken, defective
Slave control board defective
Reconnect the connector.
Replace the MG lift motor.
Replace the MG HP sensor.
Replace the slave control board.
Replace the motor harness.
Replace the sensor harness.
After the repairs, cancel the low performance mode, and then turn the power
off/on.
Error Name/Error Condition/Major Cause/Solution
Perfect Binder: Main grip press sensors (s) position late error
When lifting from main grip signature registration position, MG press sensors did
not go ON, even though the MG lift motor had operated for 95 ms.
MG lift motor defective