1.SC Codes
344
Error Name/Error Condition/Major Cause/Solution
Perfect Binder: Main grip motor (R) rotation error
At the start of the main grip open operation, the MG encoder sensor (R) was not
detected on/off, even after the MG motor (R) had operated for 200 ms.
Main grip motor (R) defective
Main grip encoder sensor (R) defective
Connector or harness loose, broken, defective
Slave control board defective
Reconnect the connector.
Replace the main grip motor (R).
Replace the main grip encoder sensor (R).
Replace the slave control board.
Replace the motor harness.
Replace the sensor harness.
After the repairs, cancel the low performance mode, and then turn the power
off/on.
Error Name/Error Condition/Major Cause/Solution
Perfect Binder: Main grip open sensor (F) late error
At the start of the main grip open operation, the MG open sensor (F) did not go
ON, even after the MG motor (R) had operated for 3000 ms.
Main grip motor (F) defective
MG open sensor (F) defective
Connector or harness loose, broken, defective
Slave control board defective
Reconnect the connector.
Replace the MG motor (F).
Replace the MG open sensor (F).
Replace the slave control board.
Replace the motor harness.
Replace the sensor harness.
After the repairs, cancel the low performance mode, and then turn the power
off/on.
Error Name/Error Condition/Major Cause/Solution
Perfect Binder: Main grip open sensor (F) lag error
At the start of the main grip close operation, the MG open sensor (F) did not go
OFF, even after the MG motor (F) had operated for 500 ms.