1.SC Codes
367
Error Name/Error Condition/Major Cause/Solution
Reconnect the connector.
Replace the PSU Cooling Fan 1 on the LCT2.
Replace the harness
Replace the PSU.
Replace the PCB.
Error Name/Error Condition/Major Cause/Solution
LCT2: PSU Cooling Fan 2 error
Cooling fan alarm “H (error)” is detected while the PSU Cooling Fan 2 on the
LCT2 is ON.
PSU Cooling Fan 2 on the LCT2 defective
Connector disconnected
Harness broken
PSU defective
PCB defective
Reconnect the connector.
Replace the PSU Cooling Fan 1 on the LCT2.
Replace the harness
Replace the PSU.
Replace the PCB
Error Name/Error Condition/Major Cause/Solution
LCT2: Bridge Unit Cooling Fan error
Cooling fan alarm “H (error)” is detected while the cooling fan on the bridge unit
of LCT2 is ON.
Connector disconnected
Harness broken
PCB on the LCT2 defective
Reconnect the connector.
Replace the cooling fan.
Replace the harness
Replace the PCB on the LCT2.