RIGOL
© 2008 RIGOL Technologies, Inc.
Users Guide for DG10× 2 Series
5-6
Input Level
TTL-compatible
Slope
Rising or falling (selectable)
Pulse Width
> 100 ns
Input Impedance
> 10 k, DC coupled
Linear Sweep
< 500 µs (typical)
Latency Sweep
< 500 ns (typical)
Trigger Output
Level
TTL-compatible into >1k
Pulse Width
> 400ns typical
Output Impedance
50, typical
Maximum Rate
1 MHz
Sync Output (CH1)
Level
TTL-compatible into >1k
Pulse Width
> 50ns (typical)
Output Impedance
50 (typical)
Maximum Frequency
2 MHz
Counter Specification
Function
Frequency, period, positive/negative Pulse width, Duty cycle
Frequency range
Single channel: 100mHz ~ 200MHz
Frequency resolution
6 digits/second
Voltage range and sensitivity (not modulated signal)
Auto mode:
1Hz to 200MHz
200 mVPP to 5 VPP
Manual mode
DC
DC offset range
± 1.5 VDC
100mHz~100MHz
20m VRMS
to ± 5 Vac+dc
100MHz~200MHz
40m VRMS
to ± 5 Vac+dc
AC
1Hz~100MHz
50m VPP
to ± 5 VPP
100MHz~200MHz
100m VPP to ± 5 VPP
Pulse width and
Duty cycle
measure
1Hz to 10MHz (100mVPP ~ 10VPP)
Input adjust
Input impedance
1MΩ