EasyManua.ls Logo

Rigol DG1022

Rigol DG1022
100 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
RIGOL DG1000 Command System
Programming Guide for DG1000
2-66
Detailed information of each command:
1.
COUPling
Syntax COUPling {OFF|ON}
Function Enable or disable coupling function.
Example COUP OFF
2.
COUPling?
Syntax
COUPling?
Function
Query the coupling state.
Return Value The query returns OFF or ON.
3.
COUPling:BASEdchannel
Syntax COUPling:BASEdchannel{:CH1|:CH2}
Function Select the base channel of channel coupling.
Example COUP:BASE:CH1
4.
COUPling:BASEdchannel?
Syntax
COUPling:BASEdchannel?
Function
Query the base channel selected.
Return Value The query returns CH1 or CH2.
5.
COUPling:PHASEDEViation
Syntax COUPling:PHASEDEViation <value>
Function Set the phase deviation of channel coupling, the default
unit is
degree.
Explanation <value>: -180° to 180
Example COUP:PHASEDEV 10
6.
COUPling:PHASEDEViation?
Syntax COUPling:PHASEDEViation?
Function
Query the phase deviation.
Return Value The query returns the phase deviation in scientific notation and the
default unit is degree, such as: 1.000000e+01.
7.
COUPling:FREQDEViation
Syntax
COUPling:FREQDEViation <value>

Other manuals for Rigol DG1022