Parameter Input
DP1308A has two methods to input parameters: dialog box input and direct input
(modify). Parameters can be inputted by the digital keyboard and unit key (direction
key).
Figure 2-1 Digital keyboard and unit key (direction key)
1. Dialog box input
When the selected menu is Volt or Curr, input desired numerical value using the
digital keyboard and then press “V”, “mV”, “A” or “mA” on the panel or in the
menu, the instrument will automatically set the voltage or current according to
the value and unit you have selected. When the selected menu is O.C.P or O.V.P,
use the same way to set O.C.P or O.V.P.
For either “Calibrate” or “Timer Setting” mode, the unit must be defined
based on practical needs after inputting numerical value, for instance, when input
a voltage value, only “mV” and “V” can be chosen as its unit.
2. Direct input(modify)
When the cursor is in the input box of voltage or current, press the “up (V)”
direction key to increase the value or press the “down (mV)” direction key to
decrease. To move the position of the cursor, press the “left (mA)” or “right (A)”
direction key.
For “I/O Setting”, respectively use the numeral key and direction key to input
numerical value and move the cursor; to backspace, press “←”.