RIGOL Chapter 2 Front Panel Operations
Users Guide for DP1308A
2-14
Multiplexed Output
Typically, all three channels of DP1308A enable to output synchronously, and each of
them could be controlled independently.
Operation Steps:
1. Power on
Press to start-up the instrument.
2. Choose and set channels
Press the channel selection button to choose the channel required to output, then
separately set the voltage and current for each of them.
3. Connect the output lead
The connection method of output terminals are given as follow, you can use a
cable with banana plug or a common cable to connect them with customers.
+25V
COM
COM
-25V
Figure 2-14 Connect the multiplexed terminals
4. Turn on the output
Press All On, and the system will prompt whether to turn on the output of all
channels. If you select ok, the On/Off button of the corresponding channel will
be light, which indicates that all channel outputs are enabled; conversely the
instrument returns the state before.
5. Set O.V.P and O.C.P
In output state, you can set O.V.P and O.C.P parameters for each channel if
necessary.