EasyManua.ls Logo

Rigol DP1308A User Manual

Rigol DP1308A
67 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
RIGOL
User’s Guide
DP1308A Programmable
Linear DC Power Supply
Aug. 2009
RIGOL Technologies, Inc.

Other manuals for Rigol DP1308A

Question and Answer IconNeed help?

Do you have a question about the Rigol DP1308A and is the answer not in the manual?

Rigol DP1308A Specifications

General IconGeneral
Number of Outputs3
DisplayLCD
Voltage Resolution1 mV
Current Resolution1 mA
InterfacesUSB, RS232
Channels3
InterfaceUSB, RS232
Display Size4.3 inch
Output Voltage Range0-30V
Ripple and Noise< 1 mVrms
Channel 1 Voltage Range0 to 30 V
Channel 2 Voltage Range0-30V
Channel 2 Current Range0-1A
Channel 3 Voltage Range0-30V
Channel 3 Current Range0-1A
Power90 W
Ripple and Noise (CV)< 1 mVrms
Ripple and Noise (CC)≤3mArms

Summary

Safety Notices

Use Proper Power Cord

Specifies using only the power cord designed for the instrument and authorized by local country.

Ground the Instrument

Emphasizes grounding the instrument through the power cord's grounding conductor.

Connect Output Wire Correctly

Advises connecting output wires according to operation methods in the guide.

Observe all Terminal Ratings

Recommends observing all ratings and marks on the instrument to avoid hazards.

Do Not Operate Without Covers

Prohibits operating the instrument with covers or panels removed.

Use Proper Fuse

Instructs to use fuses with specified voltage and current ratings.

Avoid Circuit or Wire Exposure

Warns against touching exposed connections and components when the power is on.

Do not Operate with Suspected Failures

Recommends inspection by qualified personnel if suspected damage occurs.

Keep Well Ventilation

Highlights the importance of adequate ventilation to prevent overheating.

Do not Operate in Wet/Damp Conditions

Advises against operating the instrument in humid environments to prevent shock.

Do not Operate in an Explosive Atmosphere

Warns against operating in explosive atmospheres to prevent damage or injury.

Chapter 1 Quick Start

Chapter 2 Front Panel Operations

Constant Voltage Output

Explains how to configure and enable constant voltage output for the instrument's channels.

Constant Current Output

Describes the procedure for setting up and activating constant current output on the DP1308A.

Chapter 3 Remote Control

Remote Control

Details the process of accessing and operating the instrument remotely via a web interface.

Chapter 4 Troubleshooting

Screen Dark (No Display)

Provides steps to diagnose and resolve issues where the instrument screen remains dark.

Chapter 5 Specifications

DC Output Specifications

Lists the DC output characteristics, including voltage, current, and protection ranges for all channels.

Load Regulation

Details the instrument's ability to maintain stable output voltage and current under varying load conditions.

Line Regulation

Describes how the output voltage and current remain stable despite fluctuations in the input line voltage.