EasyManuals Logo

Rigol DS1102/4B User Manual

Rigol DS1102/4B
164 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #74 background imageLoading...
Page #74 background image
RIGOL
© 2008 RIGOL Technologies, Inc.
User’s Guide for DS1000B series
2-46
Trigger Settings
Set up different trigger settings according to different trigger modes. When in the
mode of Video and Alternative, only trigger sensitivity, trigger holdoff time, holdoff
reset is adjustable.
Figure 2-56 Table 2-34 The Trigger Set Up menu
(Page 1/2 Settings for trigger coupling, trigger sensitivity and Holdoff)
Menu
Settings
Comments
Coupling
DC
AC
LF Reject
Allow all signals pass.
Block DC signals
.
Reject DC and low frequency
signals.
H
F reject
On
off
Passes high frequency
component.
Blocks high frequency
component, passes low
frequency component.
Sensitivity
<Sensitivity Setting>
Set trigger sensitivity
.
Holdoff
<Holdoff Setting>
Set time slot before another
trigger event.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rigol DS1102/4B and is the answer not in the manual?

Rigol DS1102/4B Specifications

General IconGeneral
BrandRigol
ModelDS1102/4B
CategoryTest Equipment
LanguageEnglish

Related product manuals