Trigger Settings
Set up different trigger settings according to different trigger modes. When in the
mode of Video and Alternative, only trigger sensitivity, trigger holdoff time, holdoff
reset is adjustable.
Figure 2-56 Table 2-34 The Trigger Set Up menu
(Page 1/2 Settings for trigger coupling, trigger sensitivity and Holdoff)
Menu
Settings
Comments
Coupling
DC
AC
LF Reject
Allow all signals pass.
Block DC signals
.
Reject DC and low frequency
signals.
H
F reject
On
off
Passes high frequency
component.
Blocks high frequency
component, passes low
frequency component.
Sensitivity
<Sensitivity Setting>
Set trigger sensitivity
.
Holdoff
<Holdoff Setting>
Set time slot before another
trigger event.