120 Rinnai I-Series Condensing Boiler Combi Manual
This boiler is congured for Natural Gas
only. To convert to Propane Gas, follow the
instrucons in this secon.
For installaons in Canada, the conversion
shall be carried out in accordance with the
requirements of the provincial authories
having jurisdicon and in accordance with
the requirements of the CGA-B149.1,
Natural Gas and Propane Installaon Code.
The appliance must be installed in
accordance with:
Local codes or, in the absence of local
codes, the Naonal Fuel Gas Code, ANSI
Z223.1/NFPA 54 and/or CSA B149.1,
Natural Gas and Propane Installaon
Code.
The Manufactured Home Construcon
and Safety Standard, Title 24 CFR, Part
3280 and/or CAN/CSA Z240 MH Series,
Mobile Homes, Series M86 /
Manufactured Home Construcon and
Safety Standard, Title 24 CFR.
IMPORTANT
Before you get started, conrm that
the inlet gas pressure is between the
minimum and maximum pressures
allowed for this boiler.
If subsequent conversions are made,
then a new conversion label must be
placed on the boiler to accurately
reect the gas type.
The gas supply shall be shut o prior to
disconnecng the electrical power, before
proceeding with the conversion.
CAUTION
Do not touch any other areas on the PC
board other than the described buons
while power is supplied to the appliance.
Parts of the PC board are supplied with 120
volts AC.
CAUTION
Do not touch the areas at or near the heat
exchanger or hot water lines. These areas
become very hot and could cause burns.
CAUTION
The conversion kit shall be installed by
a qualied service agency in
accordance with the manufacturers
instrucons and all applicable codes
and requirements of the authority
having jurisdicon. The informaon in
these instrucons must be followed
exactly to minimize the risk of re or
explosion or to prevent property
damage, personal injury or death. The
qualied service agency is responsible
for the proper installaon of this kit.
The installaon is not proper and
complete unl the operaon of the
converted appliance is checked as
specied in the manufacturers
instrucons supplied with the kit.
Failure to correctly assemble the
components according to these
instrucons may result in a gas leak or
explosion.
WARNING
Orice
Conversion Rang Plate
Phillips Head Screwdriver (eld-supplied)

Table of Contents

Other manuals for Rinnai I Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rinnai I Series and is the answer not in the manual?

Rinnai I Series Specifications

General IconGeneral
CategoryBoiler
BrandRinnai
SeriesI Series
Energy Star CertifiedYes
Heat Exchanger MaterialStainless Steel
MountingWall-mounted
Fuel TypeNatural Gas, Propane
Vent TypeDirect Vent
DimensionsVaries by model
WeightVaries by model
Modulation RangeUp to 10:1
Warranty12 years heat exchanger, 5 years parts