Rinnai 6 Multi Split Type AC
SAFETY PRECAUTIONS
WARNINGS FOR PRODUCT INSTALLATION
4.
5.
6.
7.
8.
9.
10.
11.
support the unit’s weight, or the installation is not done properly, the unit may dr
op and cause
serious injury and damage.
Install drainage piping according to the instructions in this manual. Impr
oper drainage may
cause water damage to your home and property.
For units that have an auxiliary electric heater, do not
install the unit within 1 metre of
any combustible materials.
Do not
install the unit in a location that may be exposed to combustible gas leaks. If
combustible
gas accumulates ar re.
Do not turn on the power until all work has been completed.
When moving or relocating the air conditioner, consult experienced service technicians for
disconnection and reinstallation of the unit.
How to install the appliance to its support, please read the information for details in "indoor unit
installation" and "outdoor unit installation" sections .
Safety
Precautions

2.
Installation must be performed according to the installation instructions. Impr
oper installation
3.
Contact an authorised service technician for r
epair or maintenance of this unit. This appliance
shall be installed in accordance with national wiring regulations.
Note about Fluorinated Gases
1.
type of gas and the amount, please refer to the relevant label on the unit itself or
the
“Owner's Manual” in the packaging of the outdoor unit.
2
equivalent or more, but of less than 50 tonnes of CO
2 equivalent, If the system has a leak-
detection system installed, it must be checked for leaks at least every 24 months.
5.
When the unit is checked for leaks, proper record-keeping of all checks is strongly recommended.
Certain types of refrigerant (Including R32) require minimum room sizes. Please ensure that these
minimum room sizes are adhered to for standard installations (up to pre-charged pipe lengths).
If larger refrigerant charges than standard are used, then consult AS/NZS 60335.2.40 to determine
WARNING
WARNING for Using R32 Refrigerant
For R32 frigerant models:
X m²
.
Appliance shall not be installed in an unventilated space, if that space is smaller than
X m²
.
(Please see the following form).
2.
Installation, service, maintenance and repair of this unit must be performed by a certified
technician.
3.
Product uninstallation and recycling must be performed by a certified technician.
4.

Other manuals for Rinnai P Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rinnai P Series and is the answer not in the manual?

Rinnai P Series Specifications

General IconGeneral
BrandRinnai
ModelP Series
CategoryAir Conditioner
LanguageEnglish

Related product manuals