SAFETY PRECAUTIONS
Do not
clean the air conditioner with combustible cleaning agents. Combustible cleaning agents
can cause re or deformation.
CLEANING AND MAINTENANCE WARNINGS
CAUTION
ELECTRICAL WARNINGS
TAKE NOTE OF FUSE SPECIFICATIONS
WARNINGS FOR PRODUCT INSTALLATION
cause water leakage, electrical shock, or re.
Safety
Precautions

1.
Installation must be performed by an authorised dealer or specialist. Defective installation can
The air conditioner’s circuit board (PCB) is designed with a fuse to provide overcurrent protection.
The specifications of the fuse are printed on the circuit board, such as :
T20A/250VAC (for <7kW unit), T30A/250VAC (for >7kW unit).
NOTE: For the units with R32 refrigerant , only the blast-proof ceramic fuse can be used.
Turn o the air conditioner and switch main power o if you are not going to use it for a long time.
Turn o and unplug the unit during storms.
Make sure that water condensation can drain unhindered from the unit.
Do not
operate the air conditioner with wet hands. This may cause electric shock.
Do not
use device for any other purpose than its intended use.
Do not
climb onto or place objects on top of the outdoor unit.
Do not
allow the air conditioner to operate for long periods of time with doors or windows open,
or if the humidity is very high.
Do not
The product must be properly earthed at the time of installation, or electrical shock may occur.
For all electrical work, follow all local and national wiring standards, r egulations, and the
Installation Manual. Connect cables tightly, and clamp them securely to prevent external for ces
also cause shock.
All electrical connections must be made accor
ding to the Electrical Connection
Diagram located on the panels of the indoor and outdoor units.
All wiring must be properly arranged to ensure that the control board cover can close properly . If
the control board cover is not closed properly, it can lead to corr osion and cause the connection
clearances in all poles, and have a leakage current that may exceed 10mA, the residual current
device(RCD) having a rated residual operating current not exceeding 30mA, and disconnection

Other manuals for Rinnai P Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rinnai P Series and is the answer not in the manual?

Rinnai P Series Specifications

General IconGeneral
BrandRinnai
ModelP Series
CategoryAir Conditioner
LanguageEnglish

Related product manuals