5.1 MSOP
I/O type: device output data, computer parse data.
Default port number is 6699.
MSOP outputs data information of the 3D environment in packets. Each MSOP packet is 1248 bytes
long and consists of reported distance, intensity, azimuth and a time stamp.
Each RS-LiDAR-32 MSOP packet payload is 1248 byte long and consists of a 42-byte header and a
1200-byte data field containing 12 blocks of 100-byte data records and a 6-byte tail.
The basic data structure of a MSOP packet for single return is as shown in Figure 6.
Figure 6: Single Return MSOP.
data packet
12 * 100 bytes = 1200 bytes
42 bytes
(21
st
~30
th
byte is
time
stamp)
4 bytes
resv. + 2
bytes
(0x00,
0xFF)