EasyManua.ls Logo

RoboSense RS-LiDAR-32 - Ucwp

Default Icon
76 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
RS-LiDAR-32 User Manual
18
Motor phase lock: 90 degree
User can reset the above information by following the example in Table 9.
Table 9: Setting of UCWP Packet.
Information
Content
Setting
Length(byte)
Header
0xAA,0x00,0xFF,0x11,
0x22,0x22,0xAA,0xAA
8
Rotate Speed
600 rpm
0x02, 0x58
2
LiDAR IP
(LIDAR_IP)
192.168.1.105
0xC0
0xA8
0x01
0x69
4
Destination PC IP
(DEST_PC_IP)
192.168.1.225
0xC0
0xA8
0x01
0xE1
4
Device MAC
Address(MAC_ADDR)
001C23174ACC
0x00, 0x1C, 0x23,
0x17, 0x4A, 0xCC
6
MSOP Port(port1)
6688
0x1A20
2
MSOP Port(port2)
6688
0x1A20
2
DIFOP Port(port3)
8899
0x22C3
2
DIFOP Port(port4)
8899
0x22C3
2
FOV starting angle
0
0x0000
2
FOV end angle
12000
0x2EE0
2
UTC_TIME
Year:2017
Month:3
Day:10
Hour:9
Minute:45
0x11
0x03
0x0A
0x09
0x2D
10

Table of Contents

Related product manuals