35 / 44
6.1.1 Oil type and viscosity
Mineral oil for general use, mineral oil for hydrostatic circuits, mineral oil for internal combustion engines or polialfaolefine synthetic oil (PAO).
Warning : Do not use mineral oil with EP additives or silicon or diester base synthetic oils.
Oil type Viscosity
Use
T
ambient
T
2
Tolio Note
Mineral
100 < 0 < 90 < 50
The pour point must be lower than the minimum
ambient temperature
Synthetic PAO
Mineral 150 < 35 < 110 < 80
Mineral 220 < 50 < 130 < 110
Installation in soundproof enclosure
Synthetic PAO 220 > 50 > 130 > 110
6.2 Filter replacement
6.2.1 ROBOX DV sizes 2-3
Suction silencer
Open the roof panel
Unloose cover knob of inlet silencer and remove the cover
Replace the filter element
Position the silencer cover and tighten cover knob
Close the roof panel
Injection silencer
Unloose cover knob of inlet silencer and remove the cover
Replace the filter element
Position the silencer cover and tighten cover knob
Close the roof panel
fig 16
6.2.2 ROBOX DV Sizes 4-5
Injection silencer
Open noise hood front doors
Unloose cover bolt of inlet silencer and remove the cover (fig 17.1)
Replace the filtering element by opening the velcro as indicated in figure. (fig 17.2, 17.3)
Reposizione new filtering element, silencer cover and tighten cover knob
Fig. 17.1 Fig. 17.2 Fig. 17.3
New filtering
element