6
Maintenance
cobas®
4800
System
Instrument
maintenance
System
Manual
Instrument
maintenance
Maintenance
for
the
instrument
is
initiated
and
managed
directly
from
the
software.
The
System
tab
shows
the
actual
maintenance
status of
the
instrument.
Maintenance
is
started
from
the
cobas
x
480
tab.
Periodic
maintenance
must
be
performed
in
order
to
ensure
safe
and
reliable
operation
of
the
instrument.
A
maintenance
procedure
is
completed
once the
procedure
has
been
fully
executed
and
the
resuits
are
within
the specifications.
Aborting
maintenance
procedures
A
maintenance
procedure
must
always
be
finalized.
Do
not
abort
a
maintenance
procedure.
Aborting
a
maintenance
procedure
will
lead
to
a
failed
status,
and
maintenance
will
need
to
be
started
again.
After
aborting
a
maintenance
procedure,
switch
off
the
instrument
and
switch
it
on
again after
10
seconds.
Infection
by
samples
and
associated
materials
Always
wear
disposable
gloves
during
maintenance.
Pay
special
attention
to
the
sharp
WARNING
edges
on
the
ISWAP
and
the
pipetting
channels.
Explosion
through
sparks
The
liquids
used
for
cleaning
are
flammable.
WARNING
Do
not
clean
the
instrument
in
the
vicinity
of
open
flames
or
devices
which
could
create
sparks.
Do
not
use
hot
air
blowers
to dry
the
instrument.
NOTICE
Instrument
damage
and malfunction
due to
incorrect
maintenance
Perform
only
the
maintenance
actions
described
in
the
daily
and
weekly
maintenance
procedures.
No
other
maintenance
is
allowed
on
any
module
of
the
instrument.
The
following
maintenance
intervals
have
to
be
followed:
Daily
maintenance
Recommended
daily
after
instrument
startup.
Weekly
maintenance
Recommended
at
the
end
of
the
week
before
shutting
down
the
instrument.
1f
an
error
is
encountered
during
a
maintenance
procedure,
try
to
resolve
the
problem
and
re-start
the
maintenance
procedure.
1f
you
cannot
resolve
the
error
yourself,
cail
Roche
Service.
Preventive
inaintenance
As
part
of the
preventive
service
program
two
scheduled
preventive
rnaintenance
service
visits
per
year
will
be
required.
Preventive
maintenance
is
performed
by
Roche
Service.
The
duration
of
each
preventative
maintenance
procedure
will
be
approximately
4
hours.
NOTICE
Instrument
damage
and
malfunction
due
to
incorrect
maintenance
Performing
daily
and
weekly
maintenance
is
mandatory.
A
run
can
only
be
started
when
maintenance
is
complete.
1f
any
parts
of
the
instrument
or
carriers
have
become
contaminated,
the
weekly
maintenance
procedure
must
be
performed.
Do
not
shut
down
the
control
unit
or
the
software
during
a
running
mainteriance
procedure.
Roche
Diagnostics
104
System
Manual
.
Version
1.0

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Roche Cobas 4800 System and is the answer not in the manual?

Roche Cobas 4800 System Specifications

General IconGeneral
BrandRoche
ModelCobas 4800 System
CategoryAnalytical Instruments
LanguageEnglish

Related product manuals