6
Maintenance
Systeni
Ivlanual
Instrument
maintenance
Counters
are
reset
to
twenty-four
hours
when
daily
maintenance
is
performed.
1f
weekly
maintenance
is
performed,
daily
maintenance
is
not
required
on
that
day.
There
is
no
processing
icon
like
an
hourglass
or
progress
bar
displayed
during
maintenance.
Perform
start
up
procedures
The system
control
unit
is
normally
left
on,
except
for
a
daily
restart
(e.g.
as
part
or
before
starting
the
daily
maintenance).
It
is
strongly
recommended
to
restart
the
system
daily.
For
startup
procedures,
if
the
control
unit
is
powered
off,
refer
to
the test-specific
Operator’s
Manual.
General
cleaning
for
the
instrument
Safety
Make
sure
that
you
have
read
and
understood
the
chapter
General
safety
information
(p.
13)
and
Safety
information
(p.
103)
The
surface
of the
instrument
should
be
cleaned
on
a
weekly
basis
with
a
lint-free
cloth
moistened
with
deionized
water.
1f
a
spul
of
reagents
occurs,
the
instrument
should
be
cleaned
with
a
70%
ethanol
solution.
Removable
internal
parts
of the
instrument,
such
as
all
carriers,
should
be
weekly
rinsed
with
deionized
water
followed
by
70%
ethanol.The
area
around
the
instrument
should
be
periodically
checked
to
ensure
that
air
flow
around
the
instrument
is
unrestricted
and
that
books, papers,
or
other
supplies
do
not
interfere
with
air flow.If
a
specimen
or
other
biohazardous
material
spills
on
the
instrument
or
any
of the
instrument
carriers,
the
area
or
carriers
should
be
cleaned
with
a
decontaminating
and
nucleic
acid
destroying
agent,
followed
by
deionized
water.
Do
not
use
other
organic
solvents
(eg.,
petroleum,
benzene,
or
other
solvents)
because
they
can
damage
plastic
materials.
Do
not
use
an
alcohol
solution
with
a
concentration
greater
than
70°/s
because
this
may
damage
transparent
viewing
windows.
Only
use
completely
dry
carriers
on
the
instrument.
Daily
maintenance
The following
tasks
are
part
of
the
daily
maintenance:
1.
Shutdown
and restart
the
system
control unit.
2.
Check
1f
instrument
deck
is
clean.
3.
Empty
the
tip
waste
and
the
liquid
waste
container
and
clean
the
tip eject
plate.
4.
The
instrument
automatically
checks
the
tightness
of
the
pipetting
channels.
5.
The
instrument
automatically
verifies
the
functioning
of
the
liquid
level
detection.
Roche
Diagnostics
System
Manual
Version
1.0
105

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Roche Cobas 4800 System and is the answer not in the manual?

Roche Cobas 4800 System Specifications

General IconGeneral
BrandRoche
ModelCobas 4800 System
CategoryAnalytical Instruments
LanguageEnglish

Related product manuals