Operation
Theory of Operation
238 MagneMotion
Rockwell Automation Publication MMI-UM007F-EN-P - September 2020
If both propulsion power and logic power are maintained and a vehicle is moved manually, the
motor resists motion of the vehicle. Once the vehicle is released, it snaps back to its original
position if it has not been moved vary far (less than 25 mm) unless the center of the magnet
array on the vehicle crossed a motor boundary.
Vehicles that have been moved too far can be recovered by deleting the moved vehicles and
restarting the section of the transport system where they are located to detect them.