3-44 Programming and Parameters
UTILITY (File E)
Diagnostics
230 [Alarm 2 @ Fault]
Captures and displays [Drive Alarm 2] at the time of
the last fault.
Read Only 212
224
thru
230
234
236
[Testpoint 1 Sel]
[Testpoint 2 Sel]
Selects the function whose value is
displayed value in [Testpoint x Data].
These are internal values that are not
accessible through parameters.
See Testpoint Codes and Functions
on
page 4-11 for a listing of available codes
and functions.
Default:
Min/Max:
Units:
499
0/999
0/65535
1
235
237
[Testpoint 1 Data]
[Testpoint 2 Data]
The present value of the function selected
in [Testpoint x Sel].
Default:
Min/Max:
Units:
Read Only
0/65535
–/+2147483647
1
Faults
238 [Fault Config 1]
Enables/disables annunciation of the listed faults.
240 [Fault Clear]
Resets a fault and clears the fault queue.
Default:
Options:
0
0
1
2
“Ready”
“Ready”
“Clear Faults”
“Clr Flt Que”
File E
Group
No.
Parameter Name and Description
See page 3-2 for symbol descriptions
Values
Related
000000000000000x
10 01234567891112131415
1 = Condition True
0 = Condition False
x = Reserved
Bit #
DigIn CflctA
DigIn CflctB
DigIn CflctC
Bipolr Cflct
MtrTyp Cflct
NP Hz Cflct
MaxFrq Cflct
VHz NegSlope
IR Vlts Rang
FlxAmps Rang
SpdRef Cflct
Ixo Volt Rang
(2)
Sleep Config
(2)
TB Ref Cflct
(1)
PTC Conflict
(1)
Nibble 1Nibble 2Nibble 3Nibble 4
x0xxxxxxxxxxxxxx
26 161718192021222324252728293031
1 = Condition True
0 = Condition False
x = Reserved
Bit #
UserSetCflct
(2)
Nibble 1Nibble 2Nibble 3Nibble 4
(1)
Enhanced firmware 1.001 & later.
(2)
Enhanced firmware 2.001 & later.
E C
32
E C
E C
1x10001000x0xxxx
10 01234567891112131415
1 = Enabled
0 = Disabled
x = Reserved
Bit #
Factory Default Bit Values
Power Loss
UnderVoltage
Motor OverLd
Shear Pin
AutRst Tries
Decel Inhibt
Motor Therm
(1)
In PhaseLoss
(2)
Load Loss
(2)
ShearPNo Acc
(1)
Nibble 1Nibble 2Nibble 3Nibble 4
(1)
Enhanced firmware 1.001 & later.
(2)
Enhanced firmware 2.001 & later.