Measurements
R&S
®
FSW
111User Manual 1173.9411.02 ─ 19
played when you press the MEAS key or select "Select Measurement" in the configura-
tion "Overview".
When you select a measurement function, the measurement is started with its default
settings immediately and the corresponding measurement configuration menu is dis-
played. The measurement configuration menu can be displayed at any time by press-
ing the MEAS CONFIG key.
The easiest way to configure measurements is using the configuration "Overview", see
chapter 6.1, "Configuration Overview", on page 312.
In addition to the measurement-specific parameters, the general parameters can be
configured as usual, see chapter 6, "Common Measurement Settings", on page 312.
Many measurement functions provide special result displays or evaluation methods;
however, in most cases the general evaluation methods are also available, see chap-
ter 7, "Common Analysis and Display Functions", on page 440.
After a preset, the R&S FSW performs a basic frequency sweep.
Frequency Sweep....................................................................................................... 111
Zero Span................................................................................................................... 112
Ch Power ACLR..........................................................................................................112
C/N, C/No....................................................................................................................112
OBW............................................................................................................................113
Spectrum Emission Mask............................................................................................113
Spurious Emissions.....................................................................................................113
APD.............................................................................................................................113
CCDF.......................................................................................................................... 114
Time Domain Power....................................................................................................114
TOI.............................................................................................................................. 114
AM Mod Depth............................................................................................................ 114
Harmonic Distortion.....................................................................................................114
EMI..............................................................................................................................115
Marker Functions........................................................................................................ 115
All Functions Off..........................................................................................................115
Frequency Sweep
A common frequency sweep of the input signal over a specified span. Can be used for
general purposes to obtain basic measurement results such as peak levels and spec-
trum traces. The "Frequency" menu is displayed. This is the default measurement if no
other function is selected.
Use the general measurement settings to configure the measurement, e.g. via the
"Overview" (see chapter 6, "Common Measurement Settings", on page 312).
Remote command:
[SENSe:]FREQuency:STARt on page 834, [SENSe:]FREQuency:STOP
on page 834