58User Manual 1173.9411.02 ─ 19
Connector Reference signal Usage
REF INPUT 1...20 MHz
0...10 dBm
To provide an external reference signal on the
R&S FSW.
REF OUTPUT 1...20 MHz
0...10 dBm
To provide the same external reference signal received
by the REF INPUT 1...20 MHZ connector to another
device, when available.
REF OUTPUT 10 MHz
10 dBm
To provide the internal reference signal from the
R&S FSW to another device continuously.
Also used to provide OCXO reference signal to another
device.
REF INPUT 100 MHz
0...10 dBm
To provide an external reference signal on the
R&S FSW.
REF OUTPUT 100 MHz
6 dBm
To provide a 100 MHz reference signal from the
R&S FSW to another device.
REF OUTPUT 640 MHz
16 dBm
To provide a 640 MHz reference signal from the
R&S FSW to another device.
SYNC TRIGGER
The SYNC TRIGGER connector can also be used to synchronize the reference fre-
quency on several devices (see chapter 3.2.2.11, "SYNC TRIGGER OUTPUT/INPUT",
on page 56).
3.3 Trying Out the Instrument
This chapter introduces the most important functions and settings of the R&S FSW
step by step. The complete description of the functionality and its usage is given in the
R&S FSW User Manual. Basic instrument operation is described in chapter 3.4, "Oper-
ating the Instrument", on page 73.
Prerequisites
The instrument is set up, connected to the mains system, and started up as descri-
bed in chapter 3.1, "Preparing for Use", on page 20.
For these first measurements, you use the internal calibration signal, so you do not
need any additional signal source or instruments. Try out the following:
Measuring a Basic Signal........................................................................................59
Displaying a Spectrogram.......................................................................................61
Activating Additional Measurement Channels.........................................................62
Performing Sequential Measurements....................................................................65
Setting and Moving a Marker.................................................................................. 66
Displaying a Marker Peak List.................................................................................67
Trying Out the Instrument

Table of Contents

Related product manuals