555User Manual 1173.9411.02 ─ 19
In secure user mode, settings that are to be stored on the instrument are stored to vol-
atile memory, which is restricted to 256 MB. Thus, a "Memory full" error may occur
although the hard disk indicates that storage space is still available.
To store data permanently, select an external storage location such as a USB memory
device.
For details see chapter 3.1.7, "Protecting Data Using the Secure User Mode",
on page 37.
For details see "Protecting Data Using the Secure User Mode" in the "Data Manage-
ment" section of the R&S FSW User Manual.
Remote command:
MMEMory:STORe<n>:TRACe on page 1015
MMEMory:STORe<n>:SGRam on page 1014
Trace Export Configuration ← Export
Opens the "Traces" dialog box to configure the trace and data export settings. See
chapter 7.3.2.3, "Trace / Data Export Configuration", on page 470.
I/Q Export ← Export
Opens a file selection dialog box to select an export file to which the IQ data will be
stored. This function is only available in single sweep mode, and only in applications
that process I/Q data, such as the I/Q Analyzer or optional applications.
For details see the description in the R&S FSW I/Q Analyzer User Manual ("Importing
and Exporting I/Q Data").
Note: Secure user mode.
In secure user mode, settings that are to be stored on the instrument are stored to vol-
atile memory, which is restricted to 256 MB. Thus, a "Memory full" error may occur
although the hard disk indicates that storage space is still available.
To store data permanently, select an external storage location such as a USB memory
device.
For details see chapter 3.1.7, "Protecting Data Using the Secure User Mode",
on page 37.
For details see "Protecting Data Using the Secure User Mode" in the "Data Manage-
ment" section of the R&S FSW User Manual.
8.4.2 How to Export Trace Data and Numerical Results
The measured trace data and numerical measurement results in tables can be expor-
ted to an ASCII file. For each sweep point the measured trace position and value are
output. The file is stored with a .DAT extension. For details on the storage format see
chapter 8.4.4, "Reference: ASCII File Export Format", on page 557.
For the results of a Spectrum Emission Mask (SEM) or Spurious Emissions measure-
ment, special file export functions are available, see chapter 5.6.6.2, "How to Save
SEM Result Files", on page 229(SEM) and "Saving the Evaluation List" on page 248
(Spurious).