7. Open the PROMPT (command line window) on the computer and
change to the directory containing the NGMO-Flash files.
8. Enter DOWNLOAD 1 (for COM1) or DOWNLOAD 2 (for COM2)
into the command lines.
The entry above depends on the connection between Power
Supply NGMO and the interface COM1 or COM2 on the comput-
er.
The PROMPT shows, among others, the following message:
Wait erasing Flash Memory
and after a short while:
OK!
Thereafter appearing dots indicate the progress of the Flash
programming.
After a successful download the Power Supply NGMO should
respond again; this time by showing the version number:
x.xx
9. After a successful DOWNLOAD close the PROMPT again, as
otherwise the serial interface used will remain blocked.
10. Switch both DIP switches behind the recess back up. (Do not
forget)!
The Power Supply NGMO is now ready for operation.
12-2 3.00 / 05-2014