EasyManua.ls Logo

Rohde & Schwarz NGMO1 - Inhibit on; Fig. 8-3 NGMO Output Plug (2 Pcs.)

Rohde & Schwarz NGMO1
76 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
P
o
w
S
upp
l
y
NG
M
O
Repair
8.1.9 INHIBIT ON
Description This function is used to test whether the output drivers of the NGMO
can be switched off via the Inhibit lines.
This requires the following test set-up.
Test set-up
Fig. 8-2 Test set-up for INHIBIT ON test
Test equipment
Fig. 8-3 NGMO Output
plug (2 pcs.)
Plug both MGMO output plugs (see chapter 11) onto the two outputs
of the NGMO2, Output A and Output B.
The following connections (see photo opposite) must be available on
the NGMO output plug:
Force + with Sense +
and
Force - with Sense -.