6-48 Rosco Maximizer 2B Asphalt Distributor
Operation
For example:
Calculated Volume = 360 Gal
If Measured Volume = 340 Gal
Calculated Vol x Pump Flow / Measured Volume
= Correct GPM
360 Gal x 140 Gal / 340 Gal = 148 GPM
8. Reset the pump ow to 148 GPM to obtain an
application rate of .3 Gal/Sq.Yd.
5. Use the measuring stick or weigh the machine to
determine the quantity sprayed.
6. Calculate the expected results.
For example:
900 Ft x 12 Ft Wide x .3 Gal/Sq Yd / 9 Sq Ft/Sq Yd
= 360 Gal.
or
600 Ft x 12 Ft Wide x .3 Gal/Sq Yd / 9 Sq Ft/Sq Yd
= 240 Gal.
7. If the measured volume does not equal the
calculated volume, adjust the ow rate to make them
equal.
2
30 35 40 45 50 60 70 80 90 100 120 150 200 250 300 350 400
1500120010009008007006005004504003503002502001501201009080
000
30
25
300 350 400 450 500 600 700 800 900 1000 1200 1500 2000 2500 3000 3500 4000
30 35 40 45 50 60 70 80 90 100 120 150 200 250 300 350 400 450 500
.88 1.0 1.25 1.50 2.0 2.5 3.0 3.5 4.0
25 20 15 12 10 98 76 54 3.0 2.5 2.0
800
3000 2500 2000 1500 1200 1000 800 700 600 500 450 400 350 300 250 200
700 600 500 450 400 350 300 250 200 150 120 100 90 80 70 60 50
1.5 1.2 1.0 .9 .8 .7 .6 .50 .45 .40 .35 .30 .25 .20 .15 .12 .10 .09 .08
3456
BAR LENGTH (FT)
PUMP RATE (GPM)
TRUCK SPEED (FPM)
GALLONS REQUIRED
LENGTH OF SHOT (FT)
ROAD WIDTH (FT)
LOOSE DEPTH (IN)
ROAD LENGTH (FT)
CUBIC YA RDS
APPLICATION RATE (GALLONS PER SQ YD)
78910111213141618202224
Slide Rule Application Guide
Figure 6-38
Return to
Last Viewed
Return to
Thumb Index

Table of Contents