EasyManua.ls Logo

Rosco Maximizer 2B - Handspray Mode (Bar Circulate)

Rosco Maximizer 2B
362 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
6
Rosco Maximizer 2B Asphalt Distributor 6-33
Operation
Handspray Mode (Bar Circulate)
Some operators have found that using the SPRAY/
BAR CRCLT mode (Figure 6-22) allows better control
of the handspray wand. SPRAY/BAR CRCLT mode will
also eliminate any setup of material that is still in the
spraybar. (Figure 5-2, 4 Spraybar Master switch on the
In-Cab Control Box in Bar Circulate posistion while the
mode is set to Spray/Bar Circulate.)
NOTE: This mode signicantly reduces the pump
pressure since the 2-Way and 3-Way valves are
open to the spraybar. The operator may have to
increase the pumpspeed 25 to 50 GPM (94.62
- 189.25 LPM) to get sufcient pressure to the
wand.
Return to
Last Viewed
Return to
Thumb Index

Table of Contents