Operation
20 AC-x32 Series Installation and Programming Manual
4.3.3 Changing from Normal to Bypass Mode
By default, there is no Normal/Bypass code. The Normal/Bypass code
must first be programmed to use this function (see Section 5.6 to
create/modify the Normal/Bypass Code).
To change from Normal to Bypass mode:
1. Enter the 4-digit Normal/Bypass Code.
The Mode LED flashes orange.
2. Press # to confirm the mode change.
The Mode LED turns orange.
4.3.4 Changing from Bypass Mode to Normal Mode
By default, there is no Normal/Bypass code. The Normal/Bypass code
must first be programmed to use this function (see Section 5.6 to
create/modify the Normal/Bypass Code).
To change from Bypass to Normal mode:
1. Enter the 4-digit Normal/Bypass code.
The Mode LED flashes green.
2. Press # to confirm the mode change.
The Mode LED turns orange.
4.4 REX Button
The REX button is used to open the door without the use of a PIN
code, and must be located inside the premises to be secured. It is
usually located in a convenient location, such as inside the door or at
a receptionist's desk. The function of the REX button depends on
whether the Lock Strike Relay is programmed for Fail Safe Operation
Mode
Door
Orange
Mode
Door
Orange
Mode
Door
Green
Mode
Door
Green

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rosslare AC Series and is the answer not in the manual?

Rosslare AC Series Specifications

General IconGeneral
Operating Voltage12VDC
Input Voltage12VDC
CommunicationRS-485, TCP/IP
Output Voltage12V DC
Enclosure RatingIP65
TypeAccess Control Unit

Related product manuals