36 AC-x32 Series Installation and Programming Manual
5.12 Replacing a Lost Programming Code
To be able to replace a lost programming code, the controller
must be in Normal mode. Before proceeding, verify that the
Mode LED is green.
1. Remove power from the unit.
2. Press the REX button.
3. Apply power to the unit while pressing the REX button.
4. Release the REX button.
5. You have 15 seconds to program a new Programming code into
the unit using the initial default code 1234 before the controller
reverts to the existing code.
5.13 Replacing a Lost Normal/Secure Code
To be able to replace lost Normal/Secure code, the controller
must be in Secure mode. Before proceeding, verify that the
Mode LED is red.
1. Remove power from the unit.
2. Press the REX button.
3. Apply power to the unit while pressing the REX button.
4. Release the REX button.
5. You have 15 seconds to program a new Normal/Secure code into
the unit using the initial default code 3838 before the controller
reverts to the existing code.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rosslare AC Series and is the answer not in the manual?

Rosslare AC Series Specifications

General IconGeneral
Operating Voltage12VDC
Input Voltage12VDC
CommunicationRS-485, TCP/IP
Output Voltage12V DC
Enclosure RatingIP65
TypeAccess Control Unit