Programming
AC-x32 Series Installation and Programming Manual 29
2. Construct the 4-digit code using the
following instructions:
First Digit
For Fail Secure Operation, the first digit should be 0.
For Fail Safe Operation the first digit should be 1.
Second Digit
Siren time in minutes (1-9, 0-disabled)
Third and Fourth Digits
Enter the number of seconds (from 1 to 99) that you want
the Lock Strike to be released.
For example, 0512 means a Fail Secure Operation consisting
of a 5-minute siren and a 12-second Lock Strike release time.
Three beeps are emitted.
The system returns to Normal mode.
5.9 Enrolling Primary and Secondary Codes
5.9.1 Primary Codes
Primary Codes can only be enrolled to an empty user slot,
meaning a slot where there is no existing Primary code.
Primary Codes must be unique, meaning that one user's Primary
Code cannot be the same as another user's Primary code.
Primary codes cannot be the same as any system codes, such as
the Normal/Secure code or Open code.
Users who hold a Primary code can gain entry only during Normal
mode.
Mode
Door
Green

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rosslare AC Series and is the answer not in the manual?

Rosslare AC Series Specifications

General IconGeneral
Operating Voltage12VDC
Input Voltage12VDC
CommunicationRS-485, TCP/IP
Output Voltage12V DC
Enclosure RatingIP65
TypeAccess Control Unit

Related product manuals