FA ROTEX Solaris RPS4 - 06/2015
6 x Control
6.3.1 Display during start-up
After switching on, the Solaris R4 controller performs a self-test
where the display elements are actuated in a targeted manner
and the setting parameters of the user level are displayed. The
following testing steps are carried out, and the results displayed
for about 2 seconds (fig. 6-5):
Immediately after switching on, the start display appears
which shows the installed software version and the serial
number of the device.
During initial commissioning, the desired display language is
queried.
After this, the current parameter settings which the user can
change are displayed.
When the operating display appears, the self test is complete.
The functions of the solar operating pump P
S
and their oper-
ating status lights can only be tested manually, for safety rea-
sons (see section 6.2.6).
Parameter Designation Value range Resolution Remark
T
K
max
Max. measured collector tem-
perature
-30 to 250 °C 1 K
T
K
min
Min. measured collector tem-
perature
-30 to 250 °C 1 K
V max Maximum flow rate
0.0 to 12.0 l/min
0.1 l/min Maximum flow measured during filling
0.0 to 20.0 l/min
0.0 to 40.0 l/min
0.0 to 100.0 l/min
PS Peak output 0,0 to 99.9 kW 0.1 kW Maximum value from 5 min output average
PS (15h) Peak value of the day 0,0 to 99.9 kW 0.1 kW
Maximum value of the peak output within the
last 15 hours
W (15h) Daily thermal yield 0.0 to 999.9 kW 0.1 kWh Thermal yield within the last 15 hours
W Total thermal yield
0.0 to 9999.9 kWh
or 10.000 to
99.999 MWh
to 0.1
0.001 kW
Total solar thermal yield determined from the
momentary output
P Momentary output 0,0 to 99.9 kW 0.1 kW Mean value during the last minute
DT Target spread 1 to 15 K 1 K
Nominal temperature difference T
V
–T
R
at mod-
ulation operation (calculated)
P1 Output stage in normal mode 0 to 100 % 1 %
Min. stage
Smallest released output stage
P1
1 to 10
0 to 100 %
1; 1 % Only accessible for an expert (see fig. 6-7)
Stage ‘On’
Running time for the solar oper-
ating pump P
S
0 to 99999 h 1 h Only accessible for an expert (see fig. 6-7)
VAR
Variable step width for opti-
mised switch-on condition
0 to 10 1 K
Tab. 6-3 Info parameter (maximum values and calculated values)
Fig. 6-5 Display during start-up