2 x Safety
FA ROTEX Solaris RPS4 - 06/2015
5
Electrical installation
Ɣ Electrical installation must be carried out only by qualified
electrical experts and in compliance with the valid electro-
technical guidelines as well as the regulations of the relevant
energy supply company (EVU).
Ɣ For the mains connection, use a separate EN 60335-1
disconnector for all-pole disconnection from the power mains
and a GFCI circuit breaker with a reaction time 0.2 s.
Ɣ Before completing the mains connection, compare the mains
voltage, indicated on the type plate (230 V, 50 Hz) with the
supply voltage.
Ɣ Before beginning work on live parts, disconnect them from the
power supply (switch off main switch, remove fuse) and
secure against unintentional restart.
Ɣ Equipment covers and service panels must be replaced as
soon as the work is completed.
Instructing the user/owner
Ɣ Before you hand over the heating system, explain to the
user/owner how to operate and check the heating system.
Ɣ Make a record of the handover by filling out and signing the
installation and instruction forms jointly with the user/owner.