EN-83Manual | TM3-Primus 9 | Specifi cations
EN
Digital Peak-/TruePeakmeter
Word width: 24 bit
Digital scales: • TP60: +3 .. –60 dB
• Dig60: 0 .. –60 dB
• Nordic: +12 .. -42 dB
• BR IIa: 7 .. 1 (British)
• VU
Headroom: –9 dBFS, beginning (turning red) at:
• –9 dBTP on TP60 scale
• –9 dBFS on Dig60 scale
• +6 dB on Nordic scale
• “6” on BR IIa scale
Integration time (Attack): acc. to standard: Sample (Dig60), 4x oversample (TP60),
10 ms (Nordic), 20 ms (BR IIa)
MC - Moving Coil
Description: Moving Coil instrument for the display of needle instru-
ments for 2-channel Stereo with different modes and
scales.
Moving Coil Instrument
Modes: PPM (BR IIa), VU, PPM (BR IIa) + Loudness (L/R + I)
PPM Mode
- Ch. arrangement: Stereo horizontal, Stereo vertical
- Scale: BR IIa: 7. .1
- Integration time: 20 ms
VU Mode
- Ch. arrangement: Stereo horizontal, Stereo vertical
- Scale analog: VU (–20 to +3 dB)
- Scale digital: VU Digital (–20 to + 3 dB)
- Lead: 0 dB, adjustable from 0 to 10 dB in steps of 1 dB
Specifi cations (continued)