EN-85Manual | TM3-Primus 9 | Specifi cations
EN
EBU R128 Loudness Mode
Target Level: –23 LUFS; adjustable from –10 to –30 LUFS in steps of
0.5 LUFS
Scale: EBU+9: +9 .. –18 LU (Loudness Units)
M Integration time: 400 ms (SQR)
S Integration Time: 3 s
I Silence Gate: –70.0 LUFS
I Relative Gate: –10.0 LU
I Tolerance Range: ±1 LU
Over Sensitivity –1 dBFS
Over hold time: 1 s
ITU BS.1771 Loudness Mode
Target Level: –24 LKFS; adjustable from –10 to –30 LKFS in steps of
0.5 LKFS
Scale: ITU+9: +9 .. –18 LU (Loudness Units)
M Integration time: 400 ms (SQR)
S Integration Time: 3 s
I Silence Gate: –70.0 LKFS
I Relative Gate: –10.0 LU
I Tolerance Range: ±2 LU
Over Sensitivity –2 dBFS
Over hold time: 1 s
ATSC A/85 Loudness Mode
Target Level: –24 LKFS; adjustable from –10 to –30 LKFS in steps of
0.5 LKFS
Scale: ATSC0: 0 .. –60 LKFS
M Integration time: 400 ms (SQR)
S Integration Time: 3 s
I Silence Gate: –70.0 LKFS
I Relative Gate: –10.0 LU
I Tolerance Range: ±2 LU
Over Sensitivity –2 dBFS
Over hold time: 1 s
Specifi cations (continued)