9 | Specifi cations EN-86
Manual | TM3-Primus
ARIB Loudness Mode
Target Level: –24 LKFS; adjustable from –10 to –30 LKFS in steps of
0.5 LKFS
Scale: ATSC0: 0 .. –60 LKFS
M Integration time: 400 ms (SQR)
S Integration Time: 3 s
I Silence Gate: –70.0 LKFS
I Relative Gate: –10.0 LU
I Tolerance Range: ±0 LU
Over Sensitivity –1 dBFS
Over hold time: 1 s
OP-59 Loudness Mode
Target Level: –24 LKFS; adjustable from –10 to –30 LKFS in steps of
0.5 LKFS
Scale: ATSC0: 0 .. –60 LKFS
M Integration time: 400 ms (SQR)
S Integration Time: 3 s
I Silence Gate: –70.0 LKFS
I Relative Gate: –10.0 LU
I Tolerance Range: ±2 LU
Over Sensitivity –2 dBFS
Over hold time: 1 s
AGCOM Loudness Mode
Target Level: –24 LKFS; adjustable from –10 to –30 LKFS in steps of
0.5 LKFS
Scale: ATSC0: 0 .. –60 LKFS
M Integration time: 400 ms (SQR)
S Integration Time: 3 s
I Silence Gate: –70.0 LKFS
I Relative Gate: –8.0 LU
I Tolerance Range: ±0.5 LU
Over Sensitivity –2 dBFS
Over hold time: 1 s