EN-87Manual | TM3-Primus 9 | Specifi cations
EN
CALM Loudness Mode
Target Level: –24 LKFS; adjustable from –10 to –30 LKFS in steps of
0.5 LKFS
Scale: ATSC0: 0 .. –60 LKFS
M Integration time: 400 ms (SQR)
S Integration Time: 3 s
I Silence Gate: –70.0 LKFS
I Relative Gate: –10.0 LU
I Tolerance Range: ±2 LU
Over Sensitivity –2 dBFS
Over hold time: 1 s
Magic LRA
Description: Loudness Range instrument in MagicLRA mode for a gra-
phical representation of loudness variances.
Loudness Range Instrument (LRA)
Display: Graphical display of the Loudness Range
Mode: MagicLRA: dynamic bargraph spreading around a zero-
point, changing its color when passing the preset ranges
Scale range: –10 LU to +10 LU
LRA low range: 5 LU
Comfort zone: 10 LU
LRA high range: outside the comfort zone
Color: green, blended in 3 steps from dark to light acc. to low
range, comfort zone, high range
Specifi cations (continued)