Table 6-11 – Parameters for the Hot Standby redundancy category page
In order to have a maximum level of flexibility, there are two modes of active hot-
standby operation:
1. Autonomous mode: The R60 units will automatically determine which one of
the units that has the best status. The base station with the best status will
become the primary/master unit, and be used for transmission and reception.
2. Forced mode: In this mode, the units will not switch automatically, but only
according to a command sent over the network. This enables a remote or
external application to decide which of the two base stations that shall be used
for transmission and reception.
If the hot-standby parameters of the two redundant R60 units conflict, a Hot Standby
Alarm will be generated (refer to section 5.2).