Saab TankRadar
®
Pro Technical Information
7-1
Edition 2. Ref. No: 306010E
7 Technical Information
Technical Data
Power supply 100-240 VAC or 24-48 VDC
Power consumption Maximum 15 W
Output cabling Twisted and shielded pair, min. 0.5 mm
2
Cable glands EExe approved (CENELEC)
Tank temperature -40-400 °C (-40-750 °F)
Ambient temperature -40-70 °C (-40-158 °F)
Standard measuring range 0-50 m (0-165 ft)
Instrument accuracy ± 5 mm (±0.2”)
Repeatability ±1 mm (±0.04”)
Processors Dual processor design. 32-bit DSP, 50
Mflops
Signal processing FFT, FHAST
Optional disturbance Saab´s Echofixer and
echo handling Multiple Echo Tracking
Level output Display panel, analog 4-20 mA signal with
digital HART,
serial Saab TRL/2 Bus
Ex approval Transmitter Head CENELEC:
(Standard and Gold versions) EEx de [ib] IIC T6.
FM:
Explosion proof Class I, Div. I & 2, Groups
A, B, C and D.