EasyManua.ls Logo

Saab TankRadar PRO - Display Panel; Analog Outputs

Saab TankRadar PRO
116 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Saab TankRadar
®
Pro Technical Information
7-3
Edition 2. Ref. No: 306010E
Display Panel
For presentation of measured values and configuration of the
transmitter
Graphical LCD display 128 x 64 pixels
Four softkeys
Text: 7 lines with 16 characters
Graphics up to 128 X 56 pixels
Supports service functions
Analog Outputs
Type Galvanically isolated, passive or active
output (external or internal loop supply)
Range 4-20 mA
Alarm level <3.6 mA or >21 mA software selectable
Resolution 0,5 µA (0.003%)
Output impedance > 10 M
Loop resistance < 700 with 24 V external supply
Voltage compliance 7-30 V