Chapter 8: Troubleshooting
Firmware – S2011 and S3012
Revision: 1 (9/98) 66 © Saftronics, Inc.
8.1 Fault Diagnosis and Corrective Actions
§ When the FP5/GP5 detects a fault, the fault is displayed on the Digital Operator and activates the fault contact output and the
motor coasts to a stop. Check the cause in the table below and take the corrective actions.
§ If the inspections or corrective actions described cannot solve the problem, contact your Saftronics representative immediately.
§ To restart, turn ON the reset input signal or press the RESET key or shut OFF the main circuit power supply once, to reset the
stop status.
§ To change the setting of a constant during fault display, first press the DSPL key to call up the monitor display. Then press
DSPL and ENTER keys simultaneously to enter PRGM mode.
NOTE: When a FWD or REV RUN command is input, the Inverter does not receive a fault reset signal. Make sure to reset after turning
OFF the FWD or REV RUN command.
efesotomasyon.com - Control Techniques,emerson,saftronics -ac drive-servo motor

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Saftronics FP5/GP5 Series and is the answer not in the manual?

Saftronics FP5/GP5 Series Specifications

General IconGeneral
BrandSaftronics
ModelFP5/GP5 Series
CategoryInverter
LanguageEnglish

Related product manuals