SECTION V MAINTENANCE
Air filter
Air filtering occurs by means of a folded paper element protected by a
container and held in a sheet metal cylinder.
WARNING: the internal cartridge of the filter does not perform any
filtration function. Its function is to prevent solid particles from entering the
inlet manifold when the filter cartridge is removed. The inner safety
element should never be cleaned but only replaced every three cleanings
of the main cartridge.
Periodically: check the efficiency of the air filter dust exhausting valve.
Air filter
130
NOTE: Check regularly that the engine air cleaner casing and element are
not damaged. Do not wash or brush the element.
NOTE: Periodically inspect air cleaner housing and element.
NOTE: The small inner secondary safety filter must never be used without
the larger outer primary filter being in place. The purpose of the secondary
safety filter is to serve as a backup to the primary and prevent dust or other
items from entering while the primary is being cleaned or replaced.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SAME SOLARIS 35 and is the answer not in the manual?

SAME SOLARIS 35 Specifications

General IconGeneral
Engine Power35 hp
PTO Power30 hp
Drive4WD
Hydraulic SystemOpen center
Hydraulic Remotes2
Lift Capacity1200 kg
Engine TypeDiesel
Transmission12 forward and 12 reverse gears

Related product manuals