SECTION V MAINTENANCE
Maintenance of Front P.T.O.
The front PTO uses oil from the gearbox.
The hydraulic circuit is fitted
with a concentric gear
pump installed inside the
P.T.O. group.
Oil is filtered by a metal
mesh filter A on the right of
the group.
Clean this filter in diesel fuel
every time you change the
gearbox oil.
When you change the oil in the
gearbox, you must also drain
the oil from the front PTO
casing by removing drain plug
B from the bottom of the
casing.
Clean any metal particles off
the drain plug magnet before
refitting the drain plug.
A - Metal mesh filter
B - Drain plug
148
A
B
DANGER: DO NOT CONNECT, DISCONNECT OR ADJUST PTO WITH
THE ENGINE RUNNING.