24 EB 8331-4 EN
Measures for preparation
5.1.2 Construction with inte-
grated yoke
Attachment
− Series V2001 Valves (DN15 to 80)
− Type 3260 (DN65 to 150)
− Type3214 (DN65 to 100)
Î Refer to Fig.5
4. Remove protective covers and unscrew
nut (6) from the valve.
5. Connect the power supply to the actuator
as described in section5.2.
6. Retract actuator stem (3) as described in
section3.3.
7. Place actuator with yoke onto the valve
and fasten tight using nut (6, width
across ats 36) with a minimum tighten-
ing torque of 150Nm.
8. When the plug stem (5) ts closely onto
the actuator stem (3), attach both stem
connector clamps (4) and fasten with
screws.
5.1.3 Construction with ring
nut
AttachmenttoSeries240Valves
Î See Fig.6 on page25.
1. Slide plug stem down to close the valve.
2. Turn the stem connector nut (8) until the
measurement x = 75mm (DN100 and
larger: x = 90 mm) from the top of the
yoke to the head of the stem connector
nut (8) is achieved. Lock this position
with the lock nut (9).
Types3374-10/-11/-21/-31
Connection with yoke
Attachment to Series V2001 Valves,
Type3260 (DN65 to 150),
Type3214 (DN65 to 100)
1
3
4
5
6
1 Actuator
2.1 Actuator yoke
2.2 Valve yoke
2.3 Bonnet
3 Actuator stem
4 Stem connector
5 Plug stem
6 Nut
7 Ring nut
8 Stem connector nut
9 Lock nut
10 Travel indicator scale
Fig.5: Attachment to Series V2001 Valves