EB 8389 EN 105
Leakage sensor
7.4 Sound level monitoring
The sound level monitoring is shown in a his-
togram. The distribution of recorded sound
levels within xed classes of valve position x
is revealed.
The leakage sensor records the sound level
every second and assigns the data into pre-
dened valve positions classes. The distribu-
tion showing how often the sound level oc-
curred within a valve position class is shown
in a bar graph.
Data are recorded in the background re-
gardless of the operating mode selected. Da-
ta logging does not need to be activated.
7.4.1 Resetting single status
messages
The measured data of the sound level moni-
toring are reset by selecting and executing
the command "Reset 'leakage detection - lev-
el'".
Operation > Reset
Reset 'leakage detection – level'
Fig.20: Diagnosis > Leakage detection > Level(x)