SINUS MINI High performance Vector Control Inverter User Manual
28
F1.05
Stopping mode
0: Dec-to-stop
1: Dec-to-stop + DC braking
2: Free run to stop
0
+
F1.06
Initial frequency of
DC injection brake
0.00~20.00Hz
0
+
F1.07
DC injection
braking time
0No operation
0.1~60.0s
0
+
F1.08
DC injection
braking current
0.0~100.0%(motor rated current)
0
+
F1.09
Acc/Dec mode
selection
0: Linear mode
1Reserved
0
+
F1.10
Reserved
Reserved
0
+
F1.11
Reserved
Reserved
0
+
F1.12
Restart after power
failure
0: disabled
1: enabled
0
+
F1.13
Delay time for
restarting after
power failure
0.0~20.0s
2.0
+
F1.14
dynamic braking
start voltage
630-710
660
F1.15
Rate of dynamic
braking
0No dynamic braking
1~100%
90
#
F1.16
Action on
frequency lower
than lower
frequency limit
0dormancy
1start, running at lower frequency limit
2Stop
0
+
F1.17
MF key function
0No operation
1reverse rotation
0
+
F1.18
Stop/reset Key
function
0action on Keypad control mode
1action on both Keypad and External terminal
2action on both Keypad and communication
0
+