SINUS MINI High performance Vector Control Inverter User Manual
25
Chapter 4 List of Parameters
Meanings of Each Item in Function Code parameter Table
Item
Meani n gs
Function code
number
The number of function code, such as F0.00
Function code
name
he name of function code, which explains the function code’s meanings.
Function code
selection
Function code parameter setting list
default value
Restore the settings of the function code after the product is delivered (see F0.19).
Order number
The order number of function code
Property
#: This function code can be changed during operation; +: This function code can only be changed
during stopping status; *: The setting of this function code is read-only and cannot be changed.
4.1 Function parameter Table
Function
code
Name
Description
Default
Property
F0.00
reserved
*
F0.01
Running command
selection
0keyboard operation
1External terminal
2Communication
0
+
F0.02
Control mode
0open loop vector control
1V/F control
1
+
F0.03
Main Frequency
Source
0 Digital set via the keyboard
1Keyboard potentiometer
2External analog signal AI1(0~10V)
3External analog signal AI2(0~20mA)
4up/down1 setting
5up/down2 setting
6Multistage speed
7PID
8Serial communication setting
9Program run
0
+