EasyManua.ls Logo

Sanwa PC20TK - Specification

Sanwa PC20TK
44 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
3
Operating system
system
Readout 4,000 counts (with unit and symbol)
Mode selection Auto or manual; only the auto mode is available for electric capacitance.
Overflow value The O.L. mark appears (except in the 750 V range for both DC and AC)
Polarity The "-" mark appears only for negative input.
Battery level
When the built-in batteries runs out, the mark appears to warn the user.
Sampling rate 3 times per second
Power supply 2 pieces of size AA manganese dry cells (1.5 V each)
Power consumption and battery life
About 7 mW in a DC range; about 150 hours of continuous operation with manganese dry cells.
Built-in fuse 1 piece of 0.5 A/250 V fuse (glass tube: 6.3 mm dia. x 30 mm)
Operating temperature and humidity range
0 °C to 40 °C; 80 % RH maximum without condensation
Storage temperature and humidity range
-10 °C to 50 °C; 70 % RH maximum without condensation
Dimensions and mass 158 (h) x 70 (W) x 41 (D) mm; approx. 230 grams
Accessories TL-21 test leads (1 set) and instruction manual (1 volume)
Accessories sold separately See paragraph 8-4.
2. Measurement range and accuracy
(accuracy-warranted temperature and humidity ranges: 23 °C ± 5 °C; 80 % maximum without condensation)
The input time of the maximum allowable load shall be within 1 minute. Adding the load exceeding
this time limit may result in burning internal components.
About a battery at the time of the shipment. There is a case that the battery does not reach
mentioned battery life, because a battery for monitors is incorporated at the time of factory shipment.
* A battery for monitors is a battery to check a function and the performance of the product.
Mode Range Input resistance, etc. Accuracy
Maximum overload protection input
DC
voltage
AC
voltage
DC
current
AC
current
Resistance
Ω
Continuity check
Diode test
Electric
capacitance
(Temperature°C)
400.0 mV
4.000 V
40.00 V
400.0 V
750 V
4.000 V
40.00 V
400.0 V
750 V
400.0
µ
A
4000
µ
A
40.00 mA
400.0 mA
400.0
µ
A
4000
µ
A
40.00 mA
400.0 mA
400.0 Ω
4.000 kΩ
40.00 kΩ
400.0 kΩ
4.000 MΩ
40.00 MΩ
40.00nF
400.0 nF
4.000
µ
F
40.00
µ
F
100.0
µ
F
−50~300 °C
100 MΩ min.
About 11 MΩ
About 10 MΩ
About 11 MΩ
About 10 MΩ
About 100 Ω
About 1 Ω
(Except for fuse resistance)
Open-circuit voltage:
About 0.4 V
Open-circuit voltage: About 0.4 V
Open-circuit voltage: About 1.5 V
About 100 Ω
About 1 Ω
(Except for fuse resistance)
(Auto-range operation only)
(A separately sold probe is used.)
±(1.0 %rdg+2dgt)
±(1.5 %rdg+9dgt)
±(1.5 %rdg+5dgt)
Sinusoidal AC 40 to 400 Hz
±(1.5 %rdg+2dgt)
±(2.0 %rdg+5dgt)
Sinusoidal AC 40 to 400 Hz
±(1.5 %rdg+5dgt)
±(1.8 %rdg+2dgt)
±(3.0 %rdg+2dgt)
Sounds below the range of 10-120 Ω.
±(8 %rdg+10dgt)
±(7 %rdg+6dgt)
±1.5 %rdg±4.8 °C
1000 VDC
750 VAC
or
peak max 1000 V
200 VDC or VAC;
the 0.5 A/250 V
fuse blows out to
protect the circuit.
500 VDC or VAC
or
peak max 700 V

Related product manuals