19
PJ NETWORK MANAGER
OWNER'S MANUAL
Customizing the status list
Changing the status column indication
1 Select Column selection from System menu. The col-
umn selection window will appear.
2 On the window, check the column name to be indi-
cated on the status list.
The mark [*] next to the column name indicates alert
item.
3 To change the order of the display column on the
status list, select a column you intend to change the
order and click To up or To down button.
4 Click OK to close setting.

When specifying the column width by numeric value, enter
number (0 to 9999) onto "Column width" text box.
Column Description
*Target name............................Name of the network equipment
*Group...........................................Group name
*Connect......................................Status of connection to the network (Connected, Un-connected)
*Drive time.................................Accumulated use time of the equipment
*Power status............................Power status of the equipment (Normal(Power-on), Normal(Standby), Power
Management, Shutter management, Power failure, lamp failure, etc.)
*Input status..............................Input signal status (Signal, No signal, Signal interrupted)
*Inside Temperature
A status....................................
Status of inside temperature A (Normal, Warning, Error)
*Inside Temperature
B status....................................
Status of inside temperature B (Normal, Warning, Error)
*Inside Temperature
C status....................................
Status of inside temperature C (Normal, Error)
*External Temperature
status
.........................................Status of external temperature (Normal, Warning, Error)
*Lamp1 status..........................Status of Lamp1 (Off, On, Error, Replace)
*Lamp2 status..........................Status of Lamp2 (Off, On, Error, Replace)
*Lamp3 status..........................Status of Lamp3 (Off, On, Error, Replace)
*Lamp4 status..........................Status of Lamp4 (Off, On, Error, Replace)
*Lamp1 time..............................Used time of Lamp1
*Lamp2 time..............................Used time of Lamp2
*Lamp3 time..............................Used time of Lamp3
*Lamp4 time..............................Used time of Lamp4
*Filter status...............................Status of airfilter (Normal, Warning, Clogged)
*Option Box
filter status............................
Status of option box filter (Normal, Error, Clogged)
*Filter time..................................Use time of airfilter
*Option Box
filter time................................
Use time of option box filter
The values in parentheses are typical value and they differ depending on the connected equipment.